The Extractor manufactured by Edulabs is a premium laboratory apparatus engineered for continuous solid-liquid solvent extractions. Constructed from high-purity BORO 3.3 Borosilicate Glass, this unit offers exceptional thermal shock resistance and near-universal chemical inertness, ensuring reliable operation under high-temperature cycling. Designed for integration into Soxhlet-style extraction setups, it features precision-ground interchangeable socket and cone joints to create leak-proof, airtight seals during analytical workflows. Ideal for organic synthesis, pharmaceutical purification, environmental contaminant analysis, and food quality testing, this extractor facilitates accurate lipid and solute isolation. Its standardized ground joints conform to rigorous international laboratory glassware standards, providing seamless compatibility with standard distillation flasks and reflux condensers. Supplied by Edulabs.

Storage Instructions

  • Store the glass extractor upright in a dry, dust-free environment or padded storage cabinet.

  • Protect ground glass joints using protective plastic caps or soft wrapping material to avoid chipping.

  • Avoid stacking heavy laboratory equipment on or against the glass apparatus.

  • Keep stored glassware away from high-traffic laboratory walkways to minimize impact risks.

  • Ensure all joints are cleaned and free of grease residue before long-term storage.

  • Store within temperature-controlled areas away from direct mechanical vibrations.

Safety Information

  • Always wear protective safety goggles, heat-resistant gloves, and a lab coat during extraction procedures.

  • Inspect the glassware thoroughly for micro-cracks, star cracks, or scratches prior to applying heat.

  • Securely clamp the extractor body to a sturdy laboratory stand using cushioned lab clamps.

  • Ensure ground glass joints are lightly greased with appropriate chemical-resistant joint grease or fitted with PTFE sleeves.

  • Never heat a completely sealed extraction system; maintain proper venting through a condenser.

  • Handle hot glass apparatus with specialized tongs or heat-insulated safety gloves.

  • Use appropriate explosion-proof heating mantles when working with flammable organic solvents.

  • Allow the apparatus to cool down to room temperature before disassembly and cleaning.

The Extractor by Edulabs is a core laboratory component designed to perform continuous extraction of soluble compounds from solid matrix samples using volatile organic solvents. Widely utilized in organic chemistry, environmental monitoring, agricultural testing, and industrial research, this extractor ensures maximum yield and efficiency during Soxhlet-type analytical routines. By cycling refluxed solvent continuously through the sample chamber, the apparatus selectively isolates lipids, oils, pesticides, and active pharmaceutical ingredients without manual intervention.

Operating on classic siphoning mechanics, solvent vapor generated in a boiling flask below ascends through a side bypass tube into a reflux condenser attached to the top socket. The condensed solvent then drips continuously onto the solid sample held within a thimble inside the extractor chamber. Once the liquid solvent level in the chamber reaches the top of the integrated siphon tube, a vacuum siphon action is triggered, automatically draining the solvent along with dissolved target compounds back down into the boiling flask. This continuous automated process guarantees exhaustive extraction while reusing a minimal volume of solvent.

Fabricated entirely from high-grade BORO 3.3 Borosilicate Glass, the extractor exhibits superior thermal performance and extraordinary resistance to chemical attack by acids, halogenated organic solvents, and neutral solutions. Its robust wall thickness and low coefficient of thermal expansion protect against cracking or structural failure during sudden thermal fluctuations. Featuring precisely ground upper sockets and lower cones, the unit creates secure, standardized connections that prevent vapor leakage, ensuring a closed-system operation essential for safety and sample preservation.

Engineered to meet stringent laboratory standards, the Edulabs Extractor easily integrates into standard chemistry laboratory setups. Its modular joint design allows full inter-compatibility with standard flasks, thimbles, and reflux condensers. By choosing Edulabs, laboratories receive high-precision glass instrumentation built for longevity, accurate analytical repeatability, and optimal laboratory safety.

Key Features

  • Fabricated from premium BORO 3.3 Borosilicate Glass for superior chemical and thermal durability.

  • Features precision-ground interchangeable socket and cone joints for vapor-tight seals.

  • Enables automated, continuous solid-liquid extraction routines.

  • Excellent resistance to aggressive organic solvents, acids, and thermal stress.

  • Standardized joint dimensions for seamless integration with standard laboratory glassware.

  • High transparency for clear visual monitoring of solvent cycling and siphon action.

  • Uniform wall thickness provides enhanced mechanical strength and heat distribution.

  • Ideal for isolation of fats, lipids, essential oils, and environmental pollutants.

  • Low coefficient of thermal expansion ensures stability during rapid temperature changes.

  • Manufactured under strict quality control standards for maximum laboratory reliability.

Technical Specifications

Parameter Specification
Product Name Extractor
Material BORO 3.3 Borosilicate Glass
Standard Standard Laboratory Glassware Standard
Capacity 60 ML, 100 ML, 200 ML, 250 ML, 500 ML, 1000 ML
Joint Types Interchangeable Ground Glass Joints (Socket / Cone)
Chemical Resistance High resistance to acids, organic solvents, and neutral liquids
Thermal Shock Resistance High thermal shock resistance
Application Continuous Solid-Liquid Solvent Extraction
Grade Laboratory Grade

Available Models

Item Code Capacity Socket Cone Pack
SL.2307.14 60 ML 34/35 24/29 1
SL.2307.15 100 ML 40/38 24/29 1
SL.2307.16 100 ML 45/40 29/32 1
SL.2307.17 200 ML 50/42 24/29 1
SL.2307.18 250 ML 45/40 29/32 1
SL.2307.19 500 ML 60/46 29/32 1
SL.2307.20 1000 ML 71/55 29/32 1

Applications

  • Lipid and crude fat determination in food and agricultural products.

  • Extraction of active pharmaceutical ingredients (APIs) from natural plant materials.

  • Isolation of environmental pollutants, pesticides, and hydrocarbons from soil samples.

  • Essential oil extraction in cosmetic and fragrance research laboratories.

  • Quality control testing in petrochemical and polymer processing industries.

  • Soluble matter extraction in botanical, herbal, and nutra-ceutical testing.

  • Organic synthesis and purification routines in academic chemistry laboratories.

  • Waste-water and solid sludge constituent extraction for environmental compliance.

  • Analytical sample preparation prior to gas or liquid chromatography.

  • Research and development in natural product chemistry.

Note

Edulabs also offers a comprehensive range of laboratory glassware, laboratory plasticware, laboratory chemicals, laboratory instruments, laboratory equipment, scientific apparatus, educational laboratory equipment, and customized laboratory solutions for educational institutions, research laboratories, pharmaceutical institutions, healthcare facilities, biotechnology laboratories, environmental testing laboratories, food and beverage laboratories, and industrial quality control laboratories. Contact Edulabs for bulk orders and OEM requirements.

Reviews

There are no reviews yet.

Be the first to review “Extractor”

Your email address will not be published. Required fields are marked *

Scroll to Top